Effects of water boiling, microwave, and water bath post-polymerization on mechanical properties of acrylic denture resins
Main Article Content
Abstract
Acrylic restorations in the mouth are exposed to strong occlusal forces. Their mechanical properties depend on the type and method of their polymerization. The aim of this study is a comparative analysis of mechanical properties (flexural strength and modulus of elasticity) of acrylic materials before and after the post-polymerization treatments (water boiling, microwave irradiation and water storage). The study included denture base resins, as well as an acrylate for orthodontic appliances impregnated with aesthetic beads. Flexural strength, modulus of elasticity and the deflection were measured immediately after polymerization, after a hot and microwave post-polymerization and after immersion in a water bath at the temperature of 37 °C. The applied post-polymerization methods resulted in an increase in flexural strength and modulus of elasticity relative to the initial values for all tested materials. Being aware of the reduction in fracture risk of dental prosthesis after a proposed post-polymerization procedure, it could be used in all clinical situations where there is an increased risk of damage to dentures.
Article Details
Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
Authors grant to the Publisher the following rights to the manuscript, including any supplemental material, and any parts, extracts or elements thereof:
- the right to reproduce and distribute the Manuscript in printed form, including print-on-demand;
- the right to produce prepublications, reprints, and special editions of the Manuscript;
- the right to translate the Manuscript into other languages;
- the right to reproduce the Manuscript using photomechanical or similar means including, but not limited to photocopy, and the right to distribute these reproductions;
- the right to reproduce and distribute the Manuscript electronically or optically on any and all data carriers or storage media – especially in machine readable/digitalized form on data carriers such as hard drive, CD-Rom, DVD, Blu-ray Disc (BD), Mini-Disk, data tape – and the right to reproduce and distribute the Article via these data carriers;
- the right to store the Manuscript in databases, including online databases, and the right of transmission of the Manuscript in all technical systems and modes;
- the right to make the Manuscript available to the public or to closed user groups on individual demand, for use on monitors or other readers (including e-books), and in printable form for the user, either via the internet, other online services, or via internal or external networks.
How to Cite
References
Kusdhany L, Nathaniel M, Dyas R, IndrasariM, Masulili C, Rahardjo T, Agustin D, Hogervorst E. Impact of using denture on cognitive function in the elderly. J Int Dent Med Res. 2016; 9: 287-292.
Felicita M, Koesmaningati H, Dewi R. Relation between tooth loss and denture wearing toward nutritional status. J Int Dent Med Res. 2016; 9: 317-321.
Darbar U, Huggett R, Harrison A. Denture fracture—a survey. Br Dent J. 1994; 176:342-345.
Chitchumnong P, Brooks S, Stafford G. Comparison of three- and four-point flexural strength testing of denture-base polymers. Dent Mater. 1989; 5:2-5.
Zappini G, Kammann A, Wachter W. Comparison of fracture tests of denture base materials. J Prosthet Dent. 2003; 90:578-585.
Lai C, Tsai M, Chen M, Chang H, Tay H. Morphology and properties of denture acrylic resins cured by microwave energy and conventional water bath. Dent Mater. 2004; 20: 133–141.
Arima T, Murata H, Hamada T. Properties of highly cross-linked autopolymerizing reline acrylic resin. J Prosthet Dent. 1995; 73:55-59.
Bayraktar G, Duran O, Bural C, Guvener B. Effects of water storage of E-glass fiber reinforced denture base polymers on residual methyl methacrylae content. J Biomed Mater Res Part B: Appl Biomater. 2004; 70: 161-166.
Dogan A, Bek B, Cevik N, Usanmaz A. The effect of preparation conditions of acrylic denture base materials on the level of residual monomer, mechanical properties and water absorption. J Dent. 1995; 23: 313–318.
Pfeiffer P, Rosenbauer E. Residual methyl methacrylate monomer, water sorption, and water solubility of hypoallergenic denture base materials. J Prosthet Dent. 2004; 92: 72-78.
Lung C, Darvell B. Minimization of inevitable residual monomer in denture base acrylic. Dent Mater. 2005; 21: 1119–1128.
Lung C, Darvell B. Methyl methacrylate monomerpolymer equilibrium in solid polymer. Dent Mater. 2007; 23: 88–94.
Bartolini J, Murchison D, Wofford D, Sarkar N. Degree of conversion in denture base materials for varied polymerization techniques. J. Oral Rehabil. 2000; 27: 488–493.
Pfeifer CS, Shelton ZR, Braga RB, Windmoller D, Machado JS, Stansbury JW. Characterization of dimethacrylate polymeric networks: a study of crosslinked structure formed by monomers used in dental composites. Eur Polymer J. 2011; 47: 162-170.
Jorge J, Giampaolo E, Machado A, Vergani E. Cytotoxicity of denture base acrylic resins: A literature review. J Prosthet Dent. 2003; 90: 190-193.
Vergani C, Seo R, Pavarina A, dos Santos Nunes Reis J. Flexural strength of autopolymerizing denture reline resins with microwave postpolymerization treatment. J Prosthet Dent. 2005; 93: 577–583.
Blagojevic V, MurphyV. Microwave polymerization of denture base materials. A comparative study. J. Oral Rehabil. 1999; 26: 804 -808.
Urban V, Machado A, Vergani C, Giampaolo E, Pavarina A, Almeida F, Cass Q. Effect of water-bath post-polymerization on the mechanical properties, degree of conversion, and leaching of residual compounds of hard chairside reline resins. Dent Mater. 2009; 25: 662–671.
Ozkomur A, Fortes C. Effects of postpolymerization microwave irradiation on provisional dental acrylics: physical and mechanical properties. Appl Biomater Funct Mater. 2016; 14(3): e302-306.
Kostić M, Krunić N, NikolićLj, Nikolić V, Najman S, Kocić J. Residual monomer content determination in some acrylic denture base materials and possibilities of its reduction. Vojnosanit Pregl. 2009; 66(3): 223-227.
Urban V, Machado A, Oliveira R, Vergani C, Pavarina A, Cass Q. Residual monomer of reline acrylic resins. Effect of water-bath and microwave postpolymerization treatments. Dent Mater. 2007; 23: 363–368.
ISO 1567:1999: Dentistry -- Denture base polymers. 1999
Lombardo C, Canevarolo S, Reis J, Machado A, Pavarina A, Giampaolo E, Vergani C. Effect of microwave irradiation and water storage on the viscoelastic properties of denture base and reline acrylic resins. J Mech Behav Biomed Mater. 2012; 25: 53 – 61.
Uzun G, Hersek N. Comparison of the fracture resistance of six denture base acrylic resins. J Biomater Appl. 2002; 17:19-29.
Janda R, Roulet JF, LattaM, Rüttermann S. The effects of thermocycling on the flexural strength and flexural modulus of modern resin-based filling materials. Dent Mater. 2006; 22: 1103–1108.
Kostic M, Krunic N, Nikolic Lj, Nikolic V, Najman S, Kostic I, Rajkovic J, Manic M, Petkovic D. Influence of Residual Monomer Reduction on Acrylic Denture Base Resins Quality. Hem Ind. 2011; 65(2): 171-177.
Pfeiffer P, Rolleke C, Sherif L. Flexural strength and moduli of hypoallergenic denture base materials. J Prosthet Dent. 2005; 93: 372-377.
OrsiI JA, Andrade VG. Effect of chemical disinfectants on the transverse strength of heat-polymerized acrylic resins submitted to mechanical and chemical polishing. J Prosthet Dent. 2004; 9: 382-388.
Stafford G, Bates J, Huggett R, Handley R. A review of the properties of some denture base polymers. J Dent. 1980; 8: 292—306.
Sato S, Cavalcante M, Orsi I, Zaniquelli O. Assessment of flexural strength and color alteration of heat-polymerized acrylic resins after simulated use of denture cleansers. Braz Dent J. 2005; 16: 124–128.
Jerolimov V, Huggett R, Brooks C, Bates J. The effect of the variations in the polymer/monomer mixing ratios on residual monomer levels and flexural properties of denture base materials. Quintessence Int. 1985; 9: 431–434.
Hayden W. Flexural strength of microwave-cured denture base plates. Gen Dent. 1986; 34: 367–371.
Vallittu P, Ruyter I, Buykuilmaz S. Effect of polymerization temperature and time on the residual monomer content of denture base polymers. Eur J Oral Sci. 1998; 106: 588-593.
Araújo P, Sayer C, Poço J, Giudici R. Technique for reducing residual monomer content in polymers, a review. Polym Eng Sci. 2002; 42: 1442-1468.
Harrison A, Huggett R. Effect of the curing cycle on residual monomer levels of acrylic resin denture base polymers. J Dent. 1992; 20: 370-374.
Thompson G, Luo Q. Contribution of postpolymerization conditioning and storage environments to the mechanical properties of three interim restorative materials. J Prosthet Dent. 2014; 112(3): 638-648.
Gad M, Fouda S, ArRejaie A, Al-Thobity A. Comparative effect of different polymerization techniques on the flexural and surface properties of acrylic denture bases. J Prosthodont. 2017 May 22. doi: 10.1111/jopr.12605.
Abdulwahhab S. High-impact strength acrylic denture base material processed by autoclave. J Prosthodont Res. 2013; 57(4): 288-293.
Vergani C, Seo R, Pavarina A, dos Santos Nunes Reis J. Flexural strength of autopolymerizing denture reline resins with microwave postpolymerization treatment. J Prosthet Dent. 2005; 93: 577-583.
Urban V, Machado A, Oliveira R, Vergani C, Pavarina A, Cass Q. Residual monomer of reline acrylic resins. Effect of water-bath and microwave post-polymerization treatments. Dent Mater. 2007; 23: 363-368.
Patil PS, Chowdhary R, Mandokar RB. Effect of microwave postpolymerization treatment on residual monomer content and the flexural strength of autopolymerizing reline resin. Indian J Dent Res. 2009; 20(3): 293-297.
Takahashi JMFK, Machado FM, Nunez JMC, Consani RLX, Mesquita MF. Relining of prosthesis with auto-polymerizing hard denture reline resins: effect of post-polymerization treatment on flexural strength. Gerodontology. 2009; 26(3): 232-236.
Azzarri M, Cortizo M, Alessandrini J. Effect of the curing conditions on the properties of an acrylic denture base resin microwave-polymerised. J Dent. 2003; 31: 463-468.
Pavarina A, Neppelenbroek K, Guinesi A, Vergani C, Machado A, Giampaolo E. Effect of microwave disinfection on the flexural strength of hard chairside reline resins. J. Dent. 2005; 33: 741–748.
Seo R, Vergani C, Pavarina A, Compagnoni M, Machado A. Influence of microwave disinfection on the dimensional stability of intact and relined acrylic resin denture bases. J Prosthet Dent. 2007; 98: 216–223.
Savabi G, Savabi O, Dastgheib B, NejatidaneshF.Effect of the processing cycle on dimensional changes of heat-polymerized denture base resins. Dent Res J (Isfahan). 2015; 12(4):301-306.
Vallittu P, Miettinen V, Alakuijala P. Residual monomer content and its release into water from denture base materials. Dent Mater. 1995; 11:338–342.
Koda T, Tsuchiya H, Yamauchi M, Ohtani S, Takagi N, Kawano J. Leachability of denture-base acrylic resins in artificial saliva. Dent Mater. 1990; 6:13–16.
Wolff D, Coupek M, Erber R, Krueger T, Krisam J, Staehle HJ, Frese C. Effect of aqueous storage on original and repair bond strength and residual monomer release of fiber reinforced composites. J Adhes Dent. 2016; 18(6): 535-543.
Krunic N, Nikolic Lj, Kostic M, Najman S, Nikolic V, Najdanovic J. In Vitro Examination of Oral Tissue Conditioners Potential Toxicity; Hem Ind. 2011; 65(6): 697-706.
Mese A. Effect of storage duration on the hardness and tensile bond strength of silicone- and acrylic resin-based resilient denture liners to a processed denture base acrylic resin. J Prosthet Dent. 2008; 99(2) 153–159.
Jorge J, Giampaolo E, Vergani C, Machado A, Pavarina A, Carlos I. Effect of post-polymerization treatments on citotoxicity of two denture base acrylic resins. J Appl Oral Sci. 2006; 14: 203-207.
Lygre G, Gjerdet N, Gronningsaeter A, Bjorkman L. Reporting on adverse reactions to dental materials-intraoral observations at clinical follow-up. Community Dent Oral Epidemiol. 2003; 31: 200-206.